NEU GRAND LIBRARY
Opening Hours: Monday-Saturday, 08:00-20:00 | E-mail: library@neu.edu.tr
 

You are not logged in Show Basket
  Home     Advanced Search     Back  
  Brief display     MARC Display     Reserve  
Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: Clinical data from 94 implants. (Ersoy, Ahmet Ersan.)
Bibliographical information (record 266616)
Help
Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: Clinical data from 94 implants.
Author:
Ersoy, Ahmet Ersan. Search Author in Amazon Books

Publisher:
Amer Acad Periodontology,
Edition:
2008.
Classification:
WU 29
URL:

http://library.neu.edu.tr:2048/login?url=http://dx.doi.org/10.1902/jop.2008.080059
Detailed notes
    - Background: Dental implant placement requires precise planning with regard to anatomic limitations and restorative goals. The aim of this study was to evaluate the match between the positions and axes of the planned and placed implants using stereolithographic (SLA) surgical guides. Methods: Ninety-four implants were placed using SLA surgical guides generated from computed tomography (CT) between 2005 and 2006. Radiographic templates were used for all subjects during CT imaging. After obtaining three-dimensional CT images, each implant was virtually placed on the CT images. SLA surgical guides, fabricated using an SLA machine with a laser beam to polymerize the liquid photo-polymerized resin, were used during implant placement. A new CT scan was taken for each subject following implant placement. Special software was used to fuse the images of the planned and placed implants, and the locations and axes were compared. Results: Compared to the planned implants, the placed implants showed angular deviation of 4.9 degrees +/- 2.36 degrees, whereas the mean linear deviation was 1.22 +/- 0.85 mm at the implant neck and 1.51 +/- 1 mm at the implant apex. Compared to the implant planning, the angular deviation and linear deviation at the neck and apex of the placed maxillary implants were 5.31 degrees +/- 0.36 degrees, 1.04 +/- 0.56 mm, and 1.57 +/- 0.97 mm, respectively, whereas corresponding figures for placed mandibular implants were 4.44 degrees +/- 0.31 degrees, 1.42 +/- 1.05 mm, and 1.44 +/- 1.03 mm, respectively. Conclusion: SLA surgical guides using CT data may be reliable in implant placement and make flapless implant placement possible.
Related links
Items (1)
Barcode
Status
Library
Section
EOL-1399
Item available
NEU Grand LibraryOnline (WU 29 .R45 2008)
Online electronic

NEAR EAST UNIVERSITY GRAND LIBRARY +90 (392) 223 64 64 Ext:5536. Near East Boulevard, Nicosia, TRNC
This software is developed by NEU Library and it is based on Koha OSS
conforms to MARC21 library data transfer rules.